| Specification |
Minimum |
Typical |
Maximum |
Unit |
RH Measurement Range RH Accuracy (overall error) |
0 |
|
100 |
% RH |
| |
±3.5* |
|
% RH |
| Measurement Range |
-35 |
|
+80 |
°C |
| -31 |
  |
+176 |
°F |
| Accuracy (overall error) |
|
±1 |
|
°C |
| |
±2 |
|
°F |
| Selectable sampling intervals |
10 sec, 1 m, 5 m, 30 m, 1 hr, 6 hrs, 12 hrs |
- |
| 1/2 AA 3.6V lithium battery life |
1 |
|
|
Year |
*This specifies the overall error in the logged readings, for relative humidity measurements between 20 and 60% RH.