Adept Scientific - International
The world's best software for research, science and engineering.
flag arrow
clearclear
Flag

 Adept Store | register Join My Adept | Flags  
Adept Scientific | 7909 Charleston Ct. | Bethesda | MD 20817 | Tel: +1 800 724 8380  
UKusdedksvnofi
Home
Products
Training
Services
 Buy Online
Downloads
Education
Support
My Adept
International |  About Us |  Blog |  Contact Us |  Press Room |  Jobs
DataShuttle

DataShuttle

Whether in the lab, field, or plant, DataShuttle provides the most accurate measurements for low level signals of any portable PC data acquisition offering on the market today.

That's because it incorporates an innovative voltage-to-frequency converter (VTF) that provides exceptional noise rejection. This unique feature enables you to obtain the same degree of measurement accuracy when reading thermocouples in an electric furnace as you can on the lab bench.

DYNAMIC RESOLUTION

Resolution improves as the signal decreases. Enjoy resolution that is 10 times better than conventional 12-and 16-bit boards at 1/10 of full scale.

LOW NOISE

Low-noise integrating converter with noise as low as 0.5 µV. Can sample at 60 or 50 Hz to eliminate power line frequency noise.

INSTALLS IN SECONDS

A single parallel cable connects the DataShuttle to a PC's parallel port. Just plug it in and it's ready to collect data!

INTEGRATED TERMINATION PANEL

The DataShuttle is a self-contained unit, with sensor termination built in. Choose from general purpose, thermocouple, RTD, or analogue isolation models. Each unit accepts a wide range of input types, with room for isolated digital modules.

COMPACT, LIGHTWEIGHT, PORTABLE

A single DataShuttle is smaller than a notebook computer and weighs less than 2 lbs. (1kg).

EXPANDABLE

Up to 15 DataShuttles can be linked together on one parallel port, providing up to 120 analogue input channels.

6 GAIN RANGES

±25 mV up to 10 V, software selected.

OPTIONAL ANALOGUE OUTPUTS

All models are available with two optional analogue outputs.

SOFTWARE SELECTABLE CONFIGURATION

Select different range, resolution, and sampling speed for each channel. Configure digital I/O lines, and more.

VERSATILE TIMING FEATURES


Use counter/timer to count pulses, measure frequency, generate pulses, or time intervals.

RUGGED

Analogue inputs are protected up to 50 V continuous, 150 V momentary. User selectable. Samples at maximum rate and averages multiple samples to pass a single sample at the chosen sample rate. Works with single or multiple channels. Noise is less than 5 µV at 1 kHz.

AUTORANGE


Set the unit to automatically select smallest range for an incoming signal. Gives higher resolution for small voltages.

MIXED INPUT TYPES

Select a different sampling rate, range, or resolution for each channel via software.

THERMOCOUPLE COMPENSATION

Precise thermocouple cold junction compensation and linearization included in the driver for 11 thermocouple types.

RTD CORRECTION

Precise linearization in driver for platinum RTDs.

MULTIPLE SOFTWARE OPTIONS

QuickLog for Windows; DASYLab; Driver interface for LabVIEW;; Development Tools for C, C ++, and Visual Basic.

CE MARK CERTIFIED

Advanced surface mount technology and high electronic standards meet CE Mark requirements for emissions and robustness.

RESOLUTION

0.0015 to 0.00009%, Dynamic (equivalent to 16 to 20-bit resolution)

SPEED

Up to 900 Hz

ANALOGUE INPUTS


8 Differential
Gain Ranges: -5 to +50 mV, -25 to +25 mV, -50 to +500 mV, -250 to +250 mV, -1 to +10 V, -5 to +5 V
Input Protection: 50 V continuous, 150 V one sec.?nonrepetitive, (operating or not operating)
Input Impedance: >20 M
Common Mode Range:  Operating: Channel-to-ground = ±7 V Non-operating: 50 V continuous, 150 V one sec.?nonrepetitive
CMRR: >100 dB on 5mV range

COUNTER/TIMER


16-Bit, up to 3 MHz

DIGITAL I/OS


8, TTL/MOS-Compatible Absolute maximum input=7 V Individually selectable as input or output

RTD CORRECTION


50 to 1000 ? alpha = .00392 or alpha = .00385

THERMOCOUPLE TYPES


E, J, K, T, B, R, S, C, D, G, N Precise isothermal cold junction compensation on TC models.
Contact factory for accuracy specifications on T/Cs & RTDs.

ANALOGUE OUTPUTS (OPTIONAL)


2 Channels (12-Bit Resolution)
Speed: Up to 2 kHz
Voltage Ranges: 0-10 V, 0-5 V, 0-2V, ±5 V, ±1 V, ±2.5 V Source/Sink. Drives 1 K load
Current Ranges: 4-20 mA, Sink; 4-20 mA, 3 to 30 V compliance
Output Protection: -12 to 36 V, short to terminals, no isolation
Output Accuracy: ±0.1% max.

REFERENCE VOLTAGE OUTPUT


6.9 V, ±5%, .0005%/?C, <10 mA

AUXILIARY POWER OUTPUT


4.7 V; Impedance = 22

OPERATING TEMPERATURE


0-50? C

PHYSICAL DIMENESIONS


Stand-alone unit with case

7.5" x 5.5" x 2.0" (19 x 14 x 5 cm)

POWER REQUIREMENTS


5 to 9 V, 300 mA (no loads), Power module included.


The Next Steps

• Ask us a question
• Buy DataShuttle Now
• View DataShuttle Pricing
• Request a Brochure
• Download a Brochure

Learn more about DataShuttle

Product Overview

DataShuttle 2000
DataShuttle 3000
DataShuttle USB
Accessories

Latest DataShuttle Information

New Features in
DataShuttle/2000

Trigger Modes
Specifications

DataShuttle Service & Support

Search the Knowledge Base
Technical support request

adept

Top of the Page

Popular Links: ChemDraw | ChemOffice | Data Acquisition | Data Analysis | Easy-PC | EndNote | Maple | MapleSim | Mathcad | MathType | Quality Analyst | Reference Manager | VisSim

Our Privacy and Terms and Conditions Statement
All Trademarks Recognised. Copyright © 2008, Adept Scientific.
Site designed and maintained by Adeptise